12 research outputs found
Lose The Views: Limited Angle CT Reconstruction via Implicit Sinogram Completion
Computed Tomography (CT) reconstruction is a fundamental component to a wide
variety of applications ranging from security, to healthcare. The classical
techniques require measuring projections, called sinograms, from a full
180 view of the object. This is impractical in a limited angle
scenario, when the viewing angle is less than 180, which can occur due
to different factors including restrictions on scanning time, limited
flexibility of scanner rotation, etc. The sinograms obtained as a result, cause
existing techniques to produce highly artifact-laden reconstructions. In this
paper, we propose to address this problem through implicit sinogram completion,
on a challenging real world dataset containing scans of common checked-in
luggage. We propose a system, consisting of 1D and 2D convolutional neural
networks, that operates on a limited angle sinogram to directly produce the
best estimate of a reconstruction. Next, we use the x-ray transform on this
reconstruction to obtain a "completed" sinogram, as if it came from a full
180 measurement. We feed this to standard analytical and iterative
reconstruction techniques to obtain the final reconstruction. We show with
extensive experimentation that this combined strategy outperforms many
competitive baselines. We also propose a measure of confidence for the
reconstruction that enables a practitioner to gauge the reliability of a
prediction made by our network. We show that this measure is a strong indicator
of quality as measured by the PSNR, while not requiring ground truth at test
time. Finally, using a segmentation experiment, we show that our reconstruction
preserves the 3D structure of objects effectively.Comment: Spotlight presentation at CVPR 201
Planogram Rebinning with the Frequency-Distance Relationship
International audienc
DOI-based reconstruction algorithms for a compact breast PET scanner
Purpose: The authors discuss the design and evaluate the performance of combined event estimation and image reconstruction algorithms designed for a proposed high-resolution rectangular breast PET scanner (PETX). The PETX scanner will be capable of measuring the depth of interaction by utilizing detector modules composed of depth-of-interaction microcrystal element (dMiCE) crystal pairs. This design allows a unique combination of event estimation and fast projection methods
Attenuation-emission alignment in cardiac PET∕CT based on consistency conditions
Purpose: In cardiac PET and PET∕CT imaging, misaligned transmission and emission images are a common problem due to respiratory and cardiac motion. This misalignment leads to erroneous attenuation correction and can cause errors in perfusion mapping and quantification. This study develops and tests a method for automated alignment of attenuation and emission data